The Ideal Logic Combi 30 is a compact, efficient gas boiler designed for central heating and instant hot water․ It offers high efficiency, condensing operation, and a user-friendly interface, making it an ideal choice for modern homes․ With outputs of 24kW, 30kW, and 35kW, it suits various household needs, providing reliable performance and energy savings․
1․1 Overview of the Boiler
The Ideal Logic Combi 30 is a wall-mounted, condensing combination boiler designed for high efficiency and reliability․ It provides both central heating and instantaneous domestic hot water, making it a versatile solution for modern homes․ With automatic spark ignition and a low water content design, it ensures quick response and optimal performance․
The boiler features a compact size, frost protection, and variable temperature controls, making it suitable for a wide range of household needs․ Its high-efficiency operation and condensing technology help reduce energy consumption and lower utility bills․
1․2 Key Features and Benefits
The Ideal Logic Combi 30 offers high efficiency with condensing technology, reducing energy consumption and lowering bills․ It features automatic bypass, frost protection, and a preheat function for domestic hot water․ The boiler includes variable temperature controls for both central heating and DHW, ensuring customizable comfort․ Its compact design and wall-mounted installation make it space-efficient․ Additionally, it provides a reliable supply of hot water and heating, making it a practical and eco-friendly choice for modern households․
Installation and Safety Guidelines
Ensure minimum clearances of 165mm above, 100mm below, and 2․5mm at the sides for safe servicing․ Follow all safety precautions and electrical supply requirements strictly․
2․1 Minimum Clearances for Installation
To ensure safe and proper installation, the Ideal Logic Combi 30 requires specific clearances․ Allow 165mm above the boiler, 100mm below, and 2․5mm at the sides․ At the front, maintain 450mm clearance for easy servicing․ Bottom clearance can be reduced to 5mm post-installation, provided an easily removable panel is fitted․ These clearances are essential for ventilation, maintenance, and compliance with safety standards․
2․2 Electrical Supply Requirements
The Ideal Logic Combi 30 requires a 230V AC, 50Hz electrical supply․ It should be connected to a dedicated 3-pin plug or spur outlet, not a 13A plug․ The boiler must be earthed for safety․ Ensure the supply cable does not exceed 3 meters in length․ The system consumes 65W, and a dedicated circuit is recommended․ Always use a qualified electrician for connections to ensure compliance with safety standards and avoid potential hazards․
2․3 Safety Precautions and Notes
Always use genuine spare parts to maintain safety and performance․ Annual servicing by a Gas Safe registered engineer is essential․ Ensure correct installation in a vertical position and proper flue alignment to avoid gas leaks․ Keep the boiler area clear of flammable materials․ Follow all instructions in the manual and use only qualified professionals for repairs․ Adhere to local gas safety regulations and manufacturer guidelines to ensure safe and efficient operation․
Boiler Operation and Controls
The Ideal Logic Combi 30 features intuitive controls for central heating and domestic hot water․ The CH temperature control adjusts radiator heat up to 80°C, while DHW preheat ensures instant hot water supply efficiently․
3․1 Controls Diagram and Explanation
The Ideal Logic Combi 30 features a straightforward control panel with essential components for managing heating and hot water․ The CH temperature control adjusts radiator heat up to 80°C, while the DHW temperature control regulates water heating․ A mode selector switches between central heating, hot water, or both․ Additional buttons include a reset button for restarting the boiler after faults․ The controls are designed for easy operation, ensuring users can efficiently manage their heating and water systems․ The clear layout and intuitive design make it user-friendly for daily adjustments and monitoring․
3․2 Starting the Boiler and Operation Modes
To start the Ideal Logic Combi 30, ensure the gas and electricity supplies are on․ Press the mode selector to choose between central heating, hot water, or both․ The boiler will ignite automatically when demand is detected․ It operates in three main modes: central heating only, hot water only, or a combination of both․ The boiler also features a preheat function for hot water, activating when demand is sensed․ This ensures efficient energy use and consistent performance across all modes․
3․3 Preheat Domestic Hot Water Function
The Ideal Logic Combi 30 features a preheat function for domestic hot water, ensuring quick access to hot water when needed․ This function activates automatically when the boiler detects demand, reducing wait times․ It works seamlessly with the boiler’s controls, providing efficient and consistent hot water delivery․ The preheat function is designed to enhance user convenience while maintaining energy efficiency, making it a practical feature for everyday use․
System Requirements and Maintenance
The Ideal Logic Combi 30 requires a water pressure of 1-1․5 bar, proper condensate drainage, and regular cleaning for optimal performance and longevity․
4․1 Water Pressure and System Requirements
The Ideal Logic Combi 30 boiler requires a water pressure of 1 to 1․5 bar for optimal operation․ The system must be designed to accommodate this pressure range, ensuring efficient heating and hot water delivery․ Regular checks and adjustments are necessary to maintain proper pressure levels․ Additionally, the boiler’s condensate drain must be correctly installed to prevent blockages and corrosion․ Proper water treatment, such as using inhibitors like Fernox or Adey MC1, is recommended to protect the system from scaling, especially in hard water areas․
4․2 Condensate Drain and Installation
The Ideal Logic Combi 30 requires a correctly installed condensate drain to ensure efficient operation and prevent corrosion․ Use approved materials like PVC or ABS for the drainpipe, avoiding bends to maintain proper flow․ The drain must be installed in accordance with local regulations and boiler specifications․ Regular inspection is essential to prevent blockages․ Ensure the condensate drain is properly connected and positioned to avoid any issues during operation․ Always follow the manufacturer’s guidelines for a safe and reliable installation․
4․3 Cleaning and General Maintenance
Regular cleaning and maintenance are crucial for optimal performance of the Ideal Logic Combi 30․ Check and clean the heat exchanger, flue, and condensate trap periodically․ Ensure the boiler casing is free from dust and debris․ Inspect all seals and connections for wear or damage․ Use a soft cloth to clean external surfaces․ For internal components, follow the manufacturer’s guidelines․ Schedule annual servicing by a qualified technician to maintain efficiency and safety․ Proper maintenance ensures reliable operation and extends the boiler’s lifespan․
Troubleshooting and Fault Codes
Refer to the fault code table for specific issues․ Check error messages and follow manual instructions for resetting or addressing problems․ Ensure proper installation and maintenance․
5․1 Common Issues and Solutions
Common issues with the Ideal Logic Combi 30 include low water pressure, error codes like E1 or E2, and no hot water or heating․ Solutions involve checking system pressure, resetting the boiler, or ensuring proper installation․ Always refer to the fault code table in the manual for specific guidance․ Regular maintenance, like cleaning and water treatment, can prevent many issues․ If problems persist, contact a certified technician for professional assistance․ Ensure all troubleshooting steps align with safety guidelines and manufacturer recommendations․
5․2 Understanding Fault Codes and Solutions
The Ideal Logic Combi 30 displays fault codes to help diagnose issues․ Codes like E1 indicate low water pressure, while E2 suggests ignition failure․ Refer to the fault code table in the manual for specific solutions․ For example, E1 can be resolved by repressurizing the system, while E2 may require a technician․ Always consult the user manual for detailed guidance on fault codes and their corresponding fixes to ensure safe and effective troubleshooting․ Regular maintenance can help prevent many common faults․
Energy Efficiency and Performance
The Ideal Logic Combi 30 offers high efficiency with condensing technology, optimizing energy use and reducing emissions․ It features weather compensation for enhanced heating efficiency and performance․
6․1 High Efficiency and Condensing Operation
The Ideal Logic Combi 30 achieves high efficiency through its condensing operation, which reuses heat from exhaust gases to maximize energy savings․ This design significantly reduces fuel consumption and emissions, making it an eco-friendly choice․ With an A-rated energy efficiency rating, it qualifies for a higher energy tax deduction․ The boiler’s advanced heat exchanger ensures optimal performance, while features like automatic bypass and DHW preheat enhance efficiency without compromising comfort․ Its condensing technology makes it a top choice for modern, energy-conscious homes․
6․2 Weather Compensation and Efficient Heating
The Ideal Logic Combi 30 incorporates weather compensation, a feature that adjusts the heating system’s output based on outdoor temperatures․ This optimizes efficiency by reducing energy consumption during milder weather and increasing heat output in colder conditions․ The system ensures consistent comfort while minimizing temperature fluctuations․ By adapting to external conditions, it maximizes energy savings and maintains reliable performance, making it an excellent choice for efficient heating year-round․
Additional Features and Settings
The Ideal Logic Combi 30 features frost protection, ensuring boiler operation in cold conditions, and a DHW preheat function for rapid hot water supply, enhancing user convenience․
7․1 Frost Protection and Boiler Restart
The Ideal Logic Combi 30 includes a frost protection feature, ensuring the boiler operates safely in cold conditions by preventing water from freezing․ In the event of a power outage, the boiler can automatically restart, maintaining heating and hot water supply once power is restored․ These features enhance reliability and user convenience, especially during harsh winter conditions, providing peace of mind and continuous performance․
7․2 Variable Temperature Controls and DHW Preheat
The Ideal Logic Combi 30 offers variable temperature controls for both central heating and domestic hot water (DHW), allowing users to customize their comfort levels․ The DHW preheat function ensures a consistent supply of hot water by preheating it before demand, enhancing efficiency․ These features provide precise control over heating and water temperature, optimizing energy use and ensuring a comfortable home environment with minimal effort․
The Ideal Logic Combi 30 is a reliable and efficient boiler, offering excellent performance for central heating and hot water․ Regular servicing and proper maintenance are key to ensuring long-term efficiency․ Always follow the user manual guidelines for adjustments and troubleshooting․ Check water pressure annually and use recommended inhibitors to prevent corrosion․ For optimal energy savings, utilize weather compensation and variable temperature controls․ Ensure all installations and repairs are carried out by qualified professionals to maintain safety and warranty validity․